Technical data
blind zone
operating range
maximum range
angle of beam spread
0 to 350 mm
3,400 mm
0 to 600 mm
6,000 mm
5,000 mm
see »detection zones«
8,000 mm
see »detection zones«
transducer frequency
resolution
reproducibility
detection zones
for different objects:
The dark grey areas represent the zone
where it is easy to recognise the normal
reflector (round bar). This indicates the typical
operating range of the sensors. The light
grey areas represent the zone where a
good reflector – for instance a
plate – can still be regognised. The
requirement here is for an optimum
alignment to the sensor. It is not
possible to evaluate ultrasonic
reflections outside this area.
ca. 120 kHz
0.18 mm
ca. 80 kHz
0.18 mm
± 0.15 %
± 0.15 %
accuracy
operating voltage U
B
voltage ripple
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
9 V to 30 V DC, reverse polarity protection
±10 %
9 V to 30 V DC, reverse polarity protection
±10 %
no-load current consumption
housing
class of protection per EN 60 529
≤ 60 mA
PBT, Polyester; ultrasonic transducer:
≤ 60 mA
PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content
IP 67
polyurethane foam, epoxy resin with glass content
IP 67
type of connection
controls
programmable
5-pin M12 circular plug, PBT
2 push-buttons
5-pin M12 circular plug,. PBT
2 push-buttons
• Teach-in via push-buttons
• LCA-2 with LinkControl
• Teach-in via push-buttons
• LCA-2 with LinkControl
indicators
synchronisation
operating temperature
storage temperature
2 LEDs yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors
2 LEDs yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors
-25°C to +70°C
-40°C to +85°C
-25°C to +70°C
-40°C to +85°C
weight
switching hysteresis
1)
switching frequency
1)
response time
1)
180 g
50 mm
240 g
100 mm
4 Hz
172 ms
3 Hz
240 ms
time delay before availability
1)
norm conformity
order no.
< 380 ms
EN 60947-5-2
< 450 ms
EN 60947-5-2
lcs+340/DD
lcs+600/DD
switched output
1) Can be programmed with LinkControl
2 x pnp, U
B
-2 V, I
max
= 2 x 200 mA
NOC/NCC adjustable, short-circuit-proof
2 x pnp, U
B
-2 V, I
max
= 2 x 200 mA
NOC/NCC adjustable, short-circuit-proof
+U
B
-U
B
D1
D2
Sync/Com
1
2
4
5
3
2 pnp switched outputs
U
lcs+340…
lcs+600…
0 m
0.8 m
1.6 m
2.4 m
3.2 m
4 m
4.8 m
5.6 m
3.4 m
Plate
Round bar ø 27 mm
1.6 m
0.8 m
0 m
0.8 m
1.6 m
0 m
1.2 m
2.4 m
3.6 m
4.8 m
6 m
7.2 m
8.4 m
Plate
Round bar ø 27 mm
2.4 m
1.2 m
0 m
1.2 m
2.4 m
*B10634*
MV-DO-121024-438041
2004/108/EC
microsonic GmbH | Hauert 16 | 44227 Dortmund | Germany | telefone +49 2 31 / 97 51 51-0 | telefax +49 2 31 / 97 51 51-51 | e-mail: [email protected] | www.microsonic.eu
The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product features.
In the »Two-way reflective barrier«
operating mode, the object has to
be within the range of 0-85 % of
the set distance.
In the Teach-in procedure »Set de-
tect point – method A« the actual
distance to the object is taught to
the sensor as the detect point. If
the object moves towards the
sensor (e.g. with level control) then
the taught distance is the level at
which the sensor has to switch the
output.
If the object to be scanned moves
into the detection area from the
side, the Teach-in procedure »Set
detect point +8 % – method B«
should be used. In this way the
switching distance is set 8 % fur-
ther than the actual measured dis-
tance to the object. This ensures a
reliable switching distance even if
the height of the objects varies
slightly.
Fig. 3: Setting the detect point for different
directions of movement of the object
The sensor can be reset to its fac-
tory setting (see »Sensor adjust-
ment with Teach-in procedure«).
Optionally all Teach-in and addi-
tional sensor parameter settings
can be made using the LinkCon-
trol adapter (optional accessory)
and the LinkControl software for
windows.