Technical data
blind zone
operating range
maximum range
angle of beam spread
0 to 350 mm
3,400 mm
0 to 600 mm
6,000 mm
5,000 mm
see »detection zones«
8,000 mm
see »detection zones«
transducer frequency
resolution
reproducibility
detection zones
for different objects:
The dark grey areas represent the zone
where it is easy to recognise the normal
reflector (round bar). This indicates the typical
operating range of the sensors. The light
grey areas represent the zone where a
good reflector – for instance a
plate – can still be regognised.. The
requirement here is for an optimum
alignment to the sensor. It is not
possible to evaluate ultrasonic
reflections outside this area.
120 kHz
0.18 mm
80 kHz
0.18 mm
± 0.15 %
± 0.15 %
accuracy
operating voltage U
B
voltage ripple
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
9 V to 30 V DC, reverse polarity protection
±10 %
9 V to 30 V DC, reverse polarity protection
±10 %
no-load current consumption
housing
class of protection per EN 60 529
≤ 60 mA
PBT, Polyester; ultrasonic transducer:
≤ 60 mA
PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content
IP 67
polyurethane foam, epoxy resin with glass content
IP 67
type of connection
controls
programmable
5-pin M12 circular plug, PBT
2 push-buttons
5-pin M12 circular plug,. PBT
2 push-buttons
• Teach-in via push-buttons
• LCA-2 with LinkControl
• Teach-in via push-buttons
• LCA-2 with LinkControl
indicators
synchronisation
operating temperature
storage temperature
LED yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors
LED yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors
-25°C to +70°C
-40°C to +85°C
-25°C to +70°C
-40°C to +85°C
weight
switching hysteresis
1)
switching frequency
1)
response time
1)
180 g
50 mm
240 g
100 mm
4 Hz
172 ms
3 Hz
240 ms
time delay before availability
1)
norm conformity
order no.
< 380 ms
EN 60947-5-2
< 450 ms
EN 60947-5-2
lcs+340/F
lcs+600/F
switched output
1) Can be programmed with LinkControl and IO-Link
Push-Pull, U
B
-3 V, -U
B
+3 V, I
max
= 100 mA
NOC/NCC adjustable, short-circuit-proof
Push-Pull, U
B
-3 V, -U
B
+3 V, I
max
= 100 mA
NOC/NCC adjustable, short-circuit-proof
+U
B
-U
B
F
Com
1
2
4
5
3
Push-Pull output in pnp circuit
U
+U
B
-U
B
F
Com
1
2
4
5
3
Push-Pull output in npn circuit
U
lcs+340...
lcs+600...
0 m
0.8 m
1.6 m
2.4 m
3.2 m
4 m
4.8 m
5.6 m
3.4 m
Plate
Round bar ø 27 mm
1.6 m
0.8 m
0 m
0.8 m
1.6 m
0 m
1.2 m
2.4 m
3.6 m
4.8 m
6 m
7.2 m
8.4 m
Plate
Round bar ø 27 mm
2.4 m
1.2 m
0 m
1.2 m
2.4 m
Fig. 4: Setting the detect point for different
directions of movement of the object
The sensor can be reset to its fac-
tory setting (see »Further set-
tings«).
Using the LinkControl adapter (op-
tional accessory) and the LinkCon-
trol software for Windows, all
Teach-in and additional sensor pa-
rameter settings can be optionally
undertaken.
microsonic GmbH | Hauert 16 | 44227 Dortmund | Germany | telephone +49 2 31 / 97 51 51-0 | telefax +49 2 31 / 97 51 51-51 | e-mail: [email protected] | www.microsonic.eu The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product fea-