System options, Community strings, Trap managers – Microsens MS400900M User Manual
Page 33

24-Port PoE Injector User’s Manual
Page 31/40
System Options
Enter the following information about the injector, as needed:
Name: Enter a name to be used for the injector.
Location: Enter the location of the PoE injector
Contact: Enter the name of contact person or organization.
Community Strings
Community strings serve as password and can be entered as one of the following:
Current Strings: User can remove the current strings or add new community
strings.
New Community Strings: Fill the column with name of string. Click
Add
.
To remove the community string, select the community string that you have
defined and click
Remove
. You cannot remove the default community string set.
RO: Read only. Enables requests accompanied by this string to display MIB-object
information.
RW: Read/write. Enables requests accompanied by this string to display MIB-object
information and to set MIB objects.
Trap Managers
A trap manager is a management station that receives traps. The management
station then generates alerts based on the received traps. If no trap manager is
defined, no traps will be issued. Create a trap manager by entering the IP address
of the station, a community string, and selects the SNMP version.
IP Address: Enter the IP address of trap manager.
Community: Enter the community string.
Trap version: Select the SNMP trap version type – v1 or v2c