Port Power Limit: Displays the power limit to a single port.
Start Condition: Displays the type of start condition.
Power Management Mode: There are 5 modes for selecting, please refer to the
table below.
And then, click
Apply
Power Management Mode interface
Management Mode:
Dynamic - based on actual power used (mode 1).
Static - preset by user (mode 2 & 3)
Class - set classification by PD, also according to IEEE 802.3af (mode 4 & 5).
Total Allocated Power:
Consumption - sum of power consumed by all ports.
Class - sum of all ports power according to their class, except for class 0 & 4 for
which the actual power consumption is summed.
Port Power Limit:
Predefined - user defined limit by port power limit.
Class - if PD’s power exceeds power according to its class.
Max - full power according to 802.3af (15.4W, 44V)
Start Condition:
N/A - no special condition.
Class - start port only, if its maximum allowed power according to its class is higher
than the user defined power limit; except for classes 0-4 for which no
start condition exists.
[Note]
PD class 1 power is 4w, PD class 2 power is 7w, PD class 0, 3, 4 power is 15.4w.