Mounting Surface Preparation

1.

Inspect the mounting surface for any machining irregularities. MicroE Systems recommends a surface finish
of better than 1.6 micrometers Ra.

2.

The straight edge (either permanent or temporary) must be sharp on the benching side in order to use it as a
guide in hand mounted applications. In order for the tape scale to be mounted close to the straight edge, the
maximum radius of 0.127 mm (0.005 inches) should be used where the edge meets the bottom of the
mounting surface.

3.

Thoroughly clean the scale mounting surface and reference edge using a cotton swab or lint-free cloth
dampened with isopropyl alcohol or acetone.

Remove all dust and particles.

4.

Mark the starting location on the mounting surface where the tape scale will be applied.