beautypg.com

Microcom 412 User Manual

Page 98

background image

Quick Reference Command Summary

Appendix D

412 Operators Manual

90

^A

^D

COMMAND

24

Change SW4: Change software dip switch #4. Below is the ^AB sequence.

12345678
^ABxxxxxxxx

*******.)))))),

******.)))))),*

*****.)))))),**

****.)))))),***

****

0000 = Not decoded (default)

****

0001 = Danish

****

0010 = 860

****

0011 = Spanish

****

0100 = 850

****

0101 = German

****

0110 = 865

****

0111 = Swiss

****

1000 = 852

****

1001 = French

****

1010 = 863

****

1011 = Swedish

****

1100 = 437

****

1101 = Italian

****

1110 = British

****

1111 = US English

****

***.)))))Q

1=Auto-size on Power-up, 0=Disable

**.))))))Q

1=Blow-hole Sensing Enable, 0=Disable

*.)))))))Q

1=External Print Request Enable,

0=Disable

.))))))))Q

1=Enable Slashed Zeros, 0=Disable

29

Printer Statistics:

0

Print statistics to serial port

1

Print statistics on a label

2

Clear the printed labels variable in the statistics

3

Clear the printed inches variable in the statistics

30

Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)

31

Show Clock: This command will send the date and time to the serial port.

32

Reset Machine: Restores printer to power-up settings. Also used to set the
non- volatile fields in memory. Section 5.3.

33

Display Model and Revision Number.