Microcom 412 User Manual
Page 48

Printer Commands
Chapter 5
412 Operators Manual
40
^A
^D
COMMAND
23
Change SW3: Software dip switch #3. Below is the ^AB sequence:
12345678
^ABxxxxxxxx
*******.
Detect Black Line On Power-up
******.Q
1=Enable Binary Compression, 0=Disable
*****.)Q
Always 0
****.))Q
Always 0
***.)))Q
Always 0
**.))))Q
1=Send Response After Print
**
0=No Response After Print
*.)))))Q
1=Invert >INPUT 1< Polarity, 0=Normal
.))))))Q
1=Disable Extended ASCII, 0=Enable
Position:
1
Extended ASCII: If enabled, characters over 7F hex will be processed.
2
Invert >INPUT 1< Polarity: The >INPUT 1< message is normally returned when
the associated reflective sensor detects a signal. The polarity of this signal
should be inverted when used as a stock level sensor. (This feature is currently
available only on the model 322M printer)
3
Response After Print: If enabled, an enquiry response will be sent back
through the first serial port after every print.
4
Always 0
5
Always 0
6
Always 0
7
Binary Compression: If enabled, the printer will accept downloaded binary
compressed font or graphic files and enquiry responses must be sent using the
five NULL character method.
8
Detect Black Line on Power-up: If this bit is set, the printer will automatically
run a few labels and correctly set the ^D91 value.