beautypg.com

Meinberg VP100 20NET User Manual

Page 7

background image

VP100/20NET

Page 7 of 25


JP7

JP16

JP19

VP100/20 NET

x

RS232

telegrams

VP100/20

RS232

x

telegrams

Fig. 3: The use of RS232 for the connection between the VP100/20 NET and the ordinary
VP100/20. The table shows the setting of jumpers in both displays.



JP7

JP8

JP9

JP10

JP11

JP14

JP15

JP16

JP17

JP18

JP19

VP100/20 NET x

x

x

x

x

passive passive 20 mA active active telegrams

VP100/20

20 mA passive passive active active x

x

x

x

x

telegrams

Fig. 4: The use of 20 mA current loop; here the outputs are active, and the inputs passive.

3

2

7

7

2

3

VP100/20 NET
Connector

OUT

VP100/20
Connector

IN

100

24

17

100

25

23

+V1

100

24

17

+V2

100

25

23

VP100/20 NET
Connector

OUT

VP100/20
Connector

IN