Meinberg VP100 20NET User Manual
Page 7

VP100/20NET
Page 7 of 25
JP7
JP16
JP19
VP100/20 NET
x
RS232
telegrams
VP100/20
RS232
x
telegrams
Fig. 3: The use of RS232 for the connection between the VP100/20 NET and the ordinary
VP100/20. The table shows the setting of jumpers in both displays.
JP7
JP8
JP9
JP10
JP11
JP14
JP15
JP16
JP17
JP18
JP19
VP100/20 NET x
x
x
x
x
passive passive 20 mA active active telegrams
VP100/20
20 mA passive passive active active x
x
x
x
x
telegrams
Fig. 4: The use of 20 mA current loop; here the outputs are active, and the inputs passive.
3
2
7
7
2
3
VP100/20 NET
Connector
OUT
VP100/20
Connector
IN
100
24
17
100
25
23
+V1
100
24
17
+V2
100
25
23
VP100/20 NET
Connector
OUT
VP100/20
Connector
IN
See also other documents in the category Meinberg Hardware:
- SHSPZF LANTIME (153 pages)
- SHSPZF LANTIME (132 pages)
- GPS180 (68 pages)
- GPS167LCD-MP (48 pages)
- GPS164xHS (34 pages)
- GPS163TDHS (34 pages)
- DCF77C51 (20 pages)
- C28COM (22 pages)
- SyncBox PTPv2 (32 pages)
- DU70 (20 pages)
- UA509P (36 pages)
- DU35S (18 pages)
- VP100 20 (22 pages)
- SDU (14 pages)
- FM614 (8 pages)
- RU226 (4 pages)
- GEN170TGP (30 pages)
- DCF77 PCI511 (22 pages)
- TCR167PCI (36 pages)
- TCR511PEX (20 pages)
- GPS169PCI (34 pages)
- DCF77 PC32E (22 pages)
- TCR510PCI (20 pages)
- USB 5131 (12 pages)
- TCR51USB (15 pages)
- GPS167PC (28 pages)
- PZF510 (26 pages)
- PZF511 (36 pages)
- PZF600 (40 pages)
- FDM509 (20 pages)
- FDM511 (26 pages)
- GPS161 (30 pages)
- GPS162 (30 pages)
- TCR510 (28 pages)
- TCR509 (22 pages)
- TCG511 (22 pages)
- DCF77 UA509 (22 pages)
- VME31 (16 pages)
- UA32S (24 pages)
- NUC80E (20 pages)
- GPS L1 (3 pages)
- DOAL (10 pages)