Technical data – Meinberg VP100 20NET User Manual
Page 24
Page 24 of 25 VP100/20NET
6. TECHNICAL DATA
Displaying
characteristics:
up to 20 characters at a time, height of characters: 50 mm, format
of characters: 5x7, pixel diameter: 5 mm, color: red or green
Network interface:
10Base-T/100Base-TX Ethernet 10/100Mbit; connector: RJ 45
Outputs:
Selectable by jumpers: RS-232/20 mA (passive/active);
DB25 female connector
Output-telegram
format:
32 ASCII characters, once per minute
Baud rate:
9600 bps (output signals)
Framing:
8N1
– 8 data bits, no parity, 1 stop bit
Relay output:
2 normally closed contacts and 2 normally open contacts,
Relay: Matsushita DS2Y
Max. allowed load: 0.3 A (at 125 V AC), 0.3 A (at 110 V DC),
1 A (at 30 V DC),
DB9 female connector
Number of messages: 31+1
Length of messages: up to 241 characters in the case of the running messages,
up to 220 characters in the case of the static, one-line messages
Internal clock:
Accuracy:
2
10
–5
(in the case of autonomous operation);
battery-powered (after the display has been turned off)
Battery backup:
In case of a power failure, the internal clock runs up to 10 years
following the date of production;
the messages remain in the memory for at least 100 hours after the
display has been turned off
Power supply:
85
– 264 V AC / 43 – 60 Hz or 120 – 375 V DC
Consumption:
up to 40 W
Fuse:
T 5 A L/250 V
–
Dimensions:
996 mm
100 mm
60 mm (not including the mounting carriers)
Weight:
5,3 kg
Protection class:
IP30
Temperature range:
0..50° C