6. TECHNICAL DATA

Displaying
characteristics:

up to 20 characters at a time, height of characters: 50 mm, format
of characters: 5x7, pixel diameter: 5 mm, color: red or green

Network interface:

10Base-T/100Base-TX Ethernet 10/100Mbit; connector: RJ 45

Outputs:

Selectable by jumpers: RS-232/20 mA (passive/active);
DB25 female connector

Output-telegram
format:

32 ASCII characters, once per minute
D:23.05.09;T:6;U:11.45.24;#*S!

Baud rate:

9600 bps (output signals)

Framing:

8N1

– 8 data bits, no parity, 1 stop bit

Relay output:

2 normally closed contacts and 2 normally open contacts,
Relay: Matsushita DS2Y
Max. allowed load: 0.3 A (at 125 V AC), 0.3 A (at 110 V DC),
1 A (at 30 V DC),
DB9 female connector

Number of messages: 31+1

Length of messages: up to 241 characters in the case of the running messages,

up to 220 characters in the case of the static, one-line messages

Internal clock:

Accuracy:

2

10

–5

(in the case of autonomous operation);

battery-powered (after the display has been turned off)

Battery backup:

In case of a power failure, the internal clock runs up to 10 years
following the date of production;
the messages remain in the memory for at least 100 hours after the
display has been turned off

Power supply:

85

– 264 V AC / 43 – 60 Hz or 120 – 375 V DC

Consumption:

up to 40 W

Fuse:

T 5 A L/250 V

Dimensions:

996 mm

100 mm

60 mm (not including the mounting carriers)

Weight:

5,3 kg

Protection class:

IP30

Temperature range:

0..50° C