beautypg.com

Hardware installation for windows 95 users – Measurement Computing Personal488 rev.1.0 User Manual

Page 14

background image

Windows 95

3-4 Installation 888996 Personal488 for Windows 95/98/Me/NT/2000/XP

Hardware Installation for Windows 95 Users

Plug-and-Play Devices

Personal488/PCI
Personal488/ATpnp
Personal488/Card

1. If you have not already done so, shutdown Windows 95 after the IEEE 488 software has been

successfully installed.

2. Remove power from the PC.

3. Physically install your interface. As a quick reference,

Personal488/PCI installs into a 32-bit PCI expansion slot,
Personal488/ATpnp installs into a 16-bit ISA expansion slot, and
Personal488/Card installs into a PC card slot.


4. Return power to the PC. After the computer powers up, Windows will detect your new hardware.

At this point refer to the full-version PDF. See page v for location.

“Non plug-and-play” Devices

Personal488/AT (AT488)
Personal488 (GP488Bplus)

Personal488/MM

1. Verify that Windows 95 has properly shutdown.

2. Remove power from the PC.

3. Physically configure the device’s jumpers and switches to match the resource settings Windows

reported during the driver installation.

Non plug-and-play board users: physically configure your board’s jumpers and switches
to match the resource settings Windows reported. If these settings conflict with other
hardware, change the jumpers, switches, and Windows Resource settings to available
resources.

Reference Note:
Refer to Chapter 4, Hardware Configuration Reference for further information
concerning jumpers and switches.

4. Physically install your interface.

5. Return power to the PC.

At this point refer to the full-version PDF. See page v for location.