DaqBoard/2000 Series & /2000c Series User’s Manual

10-18-02

Daq Systems and Device Overviews 1-27

Digital I/O

Applicable to DaqBoard/2000, /2001, /2002, /2004, /2005, /2000c, /2001c, /2002c, /2004c and /2005c

Channels: 40, expandable to 208 with external DBK options

Input Scanning Modes: 2

1.

Asynchronous, under program control at any time relative to input scanning

2.

Synchronous with input scanning

Ports: 3 x 8-bit (82C55 emulation), and 1 x 16-bit. Each port is programmable as input or output.

Input Characteristics: 100

Ω series, 20 pF to common

Input protection:

±8 kV ESD clamp diodes parallel

I/O levels: TTL

Sampling/Update rate: 200 kHz maximum

Pattern Generation Output

Applicable to DaqBoard/2000, /2001, /2002, /2004, /2005, /2000c, /2001c, /2002c, /2004c, and /2005c

The P3 16-bit digital I/O port can be configured for 16-bit pattern generation. The pattern can be
updated synchronously with an acquisition from a file. If pattern generation mode is utilized, then the
D/A outputs can only be used in an asynchronous mode. Bus mastering DMA provides CPU and
system-independent data transfers, insuring data acquisition performance irrespective of other system
activities. Streaming from disk or memory is supported, allowing continuous, nearly-infinite length,
pattern outputs (limited only by available PC system resources)

Frequency/Pulse Generators

Applicable to DaqBoard/2000, /2001, /2002, /2004, /2005, /2000c, /2001c, /2002c, /2004c, /2005c

Channels: 2 x 16-bit

Output Waveform: Square wave

Output rate: 1 MHz base rate divided by 1 to 65535 (programmable)

High level output voltage: 2.0 V minimum @ -3.75 mA, 3.0 V minimum @ -2.5 mA

Low level output voltage: 0.4 V maximum @ 2.5 mA

Frequency/Pulse Counters

Applicable to DaqBoard/2000, /2001, /2002, /2004, /2005, /2000c, /2001c, /2002c, /2004c, and /2005c

Counter inputs can be scanned synchronously along with analog and digital scanned inputs, based
either on internal programmable timer, or an external clock source. Bus mastering DMA provides
CPU and system-independent data transfers, insuring data acquisition performance irrespective of
other system activities. Counters can be configured to clear when read, or to totalize and clear under
program control.

Channels: 4 x 16-bit, cascadable as 2 x 32-bit
Input rate: 10 MHz maximum

Input Signal Range: -15 V to +15 V
Input Characteristics: 2.7 k

Ω series in parallel with 20 pF to common and 10 kΩ to +5 V

Input protection:

±8 kV ESD clamp diodes parallel

Trigger Level: TTL
Minimum pulse width: 50 ns high, 50 ns low

Included Accessories and Software

Software:

Windows Drivers (32-bit), 90-day Getting Started DaqView

Hardware: DBK205

is included with only DaqBoard/2003 and DaqBoard/2003c. This adapter option

provides screw-terminal access to the board’s four analog outputs (DAC0, DAC1, DAC2,
and DAC3), 1 digital ground, 5 analog grounds, an external clock (CLK), and an external
trigger (XTTL).