Calculating online, Calculating online -5 – Measurement Computing DASYLab User Manual User Manual
Page 15

DASYLab
© National Instruments Ireland Resources Limited
|
1-5
Figure 1-3.
Color and Line Display of a Display Window
e.
Click OK. The drawing area of the Y/t Chart display window
changes to the new color.
8.
Click Stop on the function bar to stop the measurement.
Tip
You also can press
measurement.
Calculating Online
Complete the following steps to run calculations with the Formula Interpreter
during the measurement.
1.
Click the Plus sign next to the module group Mathematics in the
browser.
a.
Select the Formula Interpreter module and drag and drop the
module into the worksheet.
b.
Double-click the Formula Interpreter module to open the dialog
box.
c.
Click the Plus sign under Input channels to create a second
channel input.
Note
Do not click the Plus button next to the channel bar. That
creates a second channel output.