Counter section

Counter type

82C54

Configuration

3 down-counters, 16 bits each
Counter 0 - independent, user configurable

Source:

user connector (Counter 0 In)

Gate:

user connector (Gate 0)

Output:

user connector (Counter 0 Out)

Counter 1 - independent, user configurable

Source:

user connector (Counter 1 In)

Gate:

user connector (Gate 1)

Output:

user connector (Counter 1 Out)

Counter 2 - independent, user configurable

Source:

1 MHz (from 10MHz Xtal via divide-by-ten) or PC SysClk (via divide by 2 circuit)
selectable by jumper

Gate:

user connector (Gate 2)

Output:

user connector (Counter 2 Out)

Clock input frequency

10 Mhz max

High pulse width (clock input)

30 ns min

Low pulse width (clock input)

50 ns min

Gate width high

50 ns min

Gate width low

50 ns min

Input low voltage

0.8V max

Input high voltage

2.0V min

Output low voltage

0.4V max

Output high voltage

3.0V min

Environmental

Operating temperature range

0 to 50°C

Storage temperature range

20 to 70°C

Humidity

0 to 95% non-condensing