WRITE

A write to this register loads the value written into DAC0’s register, but does not update the DAC output.

READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.

BASE ADDRESS + 9, DAC 0 HIGH BYTE (Read / Write)

DA8

DA9

DA10

DA11

MSb

X

X

X

X

0

1

2

3

4

5

6

7

WRITE

A write to this register loads the value written into DAC0’s register and updates DAC0’s output when the Update jumper is
set for normal mode.

READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.

6.9 D/A 1 CONTROL REGISTERS

BASE ADDRESS + 10, DAC 1 LOW BYTE (Read / Write)

DA0

LSb

DA1

DA2

DA3

DA4

DA5

DA6

DA7

0

1

2

3

4

5

6

7

WRITE

A write to this register loads the value written into DAC1’s register, but does not update the DAC output.

READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.

BASE ADDRESS + 11, DAC 1 HIGH BYTE (Read / Write)

DA8

DA9

DA10

DA11

MSb

X

X

X

X

0

1

2

3

4

5

6

7

WRITE

A write to this register loads the value written into DAC1’s register and updates DAC1’s output when the Update jumper is
set for normal mode.

READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.