Measurement Computing CIO-DAS08-AOH User Manual
Page 20

WRITE
A write to this register loads the value written into DAC0’s register, but does not update the DAC output.
READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.
BASE ADDRESS + 9, DAC 0 HIGH BYTE (Read / Write)
DA8
DA9
DA10
DA11
MSb
X
X
X
X
0
1
2
3
4
5
6
7
WRITE
A write to this register loads the value written into DAC0’s register and updates DAC0’s output when the Update jumper is
set for normal mode.
READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.
6.9 D/A 1 CONTROL REGISTERS
BASE ADDRESS + 10, DAC 1 LOW BYTE (Read / Write)
DA0
LSb
DA1
DA2
DA3
DA4
DA5
DA6
DA7
0
1
2
3
4
5
6
7
WRITE
A write to this register loads the value written into DAC1’s register, but does not update the DAC output.
READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.
BASE ADDRESS + 11, DAC 1 HIGH BYTE (Read / Write)
DA8
DA9
DA10
DA11
MSb
X
X
X
X
0
1
2
3
4
5
6
7
WRITE
A write to this register loads the value written into DAC1’s register and updates DAC1’s output when the Update jumper is
set for normal mode.
READ
A read from this register updates both DACs when the Update jumper is set for simultaneous mode. The value read contains
no meaningful information.
16