2.6 Condensate drainage connection

For T40 models fit a condensate water drainage

hose with a minimum diameter of 1” . Provide

a waste pipe with a trap with a diameter of at

least 1 1/2” at floor level.

2.7 T40 Information for the installation technician

Before starting up the machine, check that it has

been correctly installed.

1. Check that there are no gas leaks from weldings

or joints made during installation works.

2. Check that the pipes connecting the condenser

to the remote condensing unit have been well

insulated.

3. Check all wiring connections.

4. Check electrical input.

5. Check the standard pressure in the refrigerant

system.

6. Perform at least one blast freezing cycle (to the

SET temperature) and one manual defrosting

cycle. In the event that the appliance or

the remote condensing unit have not been

transported in a vertical position (e.g. on

the back) or have been overturned during

installation works, allow at least 4 hours before

starting up the equipment.

2.8 Safety and control systems

• Door microswitch: shuts down fan operation in

the cell when the door is opened.

• General fuses: protect the power circuit against

short circuiting and overloads.

• Compressor heat relay: intervenes in the event

of overloads or operating faults.

• Safety pressure switch: intervenes in the event of

excessive pressure in the refrigerant circuit.

• Plug fuses: intervene in the event of verpressure

or operating fault in the safety pressure switch

(see above).

• Chamber temperature control: operated by the

electronic board by means of a probe inside the

cell.

• Temperature control end defrost cycle:

controlled by the electronic board by means of

the probe in the evaporator.

2.9 Appliance disposal

After the useful life of the applicance has been

realized, be sure to demolish and dispose of the

machine in compliance with the regulations

applied in the country of installation,

particularly in regards to refrigerant gas and

compressor lubricant oil.