Disarming diagnostics, Arm/disarm diagnostic chart – Directed Electronics 3000 User Manual
Page 20
17
© 2 0 0 5 d i re c t e d e l e c t ro n i c s , a l l r i g h t s re s e r v e d
disarming diagnostics
Extra disarm chirps are the Tamper Alert. If four chirps are heard when
disarming, the system was triggered in your absence. If four chirps are
heard, the LED status indicator will indicate which zone was triggered
when the ignition is turned on and will repeat 5-times (refer to the
Arm/Disarm Diagnostic Chart and Table of Zones section). The system
will retain this information in its memory. Refer to the Multiple Event
Total Recall section of this guide.
arm/disarm diagnostic chart
Refer to the table of zones to identify the last zone triggered.
Action
No. of Chirps
Description
Arm
1
System armed
Arm
1 (3-sec. pause) 1
System armed with zone
active and bypassed
Disarm
2
System disarmed
Disarm
4
System disarmed with tamper alert
High Security 1
System silenced, but still armed, and
Disarm
all zone inputs are inactive and
(siren on)
monitored.
High Security 3
System silenced, but still armed, and
Disarm
a zone is still active and bypassed.
(siren on)
Disarm
5
System disarmed with a zone in NPC.