Low battery indication—level 2 – Denso BHT-7000 User Manual
Page 121
105
Chapter 4. Error Messages
Charge the
battery!
Replace the
batteries!
(When the dry battery cartridge
is loaded)
(When the rechargeable battery
cartridge is loaded)
Low battery indication—Level 2
■ Problem
When the power is turned on or during execution
of program (System Mode or application), the bat-
tery output level has lowered.
If lower battery is detected, the BHT-7000
beeps five times (for 0.1 second per beep) and
then turns itself off. Depending upon the
battery level, the beeper may not sound five
times.
■ Solution
If the BHT-7000 is loaded with the rechargeable
battery cartridge, replace or charge it. (For the
charging procedure, refer to Chapter 5, Section
5.5.)
If the BHT-7000 is loaded with the dry battery car-
tridge, replace the dry cells.