11. TROUBLESHOOTING

Problem

Possible Cause

Solution

The KanguruClone will

not start or there is no

display on the LCD

screen.

The power cable is damaged or

not connected securely.

Make sure that the power cable is not

damaged and is not loose.

The voltage of the outlet the

KanguruClone is plugged

into does not match the

KanguruClone.

Make sure that the voltage of the

outlet matches the voltage of the

KanguruClone.

The KanguruClone

cannot make copies of a

Master hard drive.

The hard drive is not connected

or was not detected by the

Kanguru Clone.

Make sure that all connected hard

drives have been successfully detected

by the KanguruClone.

The cables connecting the hard

drive are not connected securely.

Make sure that no hard drive

connection cables are loose.

The hard drive jumpers are not

set in the correct position.

Make sure that all the hard drive

jumpers are set to the Master or Cable

Select position.

The hard drive may be faulty.

Make sure that the Master hard drive is

not broken and does not have errors.

The hard drive’s format is not

supported by Brief Copy or

Resize Copy.

When executing a Brief Copy or

Resize Copy, make sure that the format

of the Master hard drive is supported.

The hard drive contains a Host

Protected Area.

Enable the HPA CHECK option under

the Advanced Setup menu.

The KanguruClone is

unstable or operates very

slowly.

The data cables from the

KanguruClone to the hard drives

are not connected securely.

Make sure that none of the data or

power cables are loose.

A hard drive may have an error

that is affecting the other hard

drives, causing slow operation.

Try to identify the faulty hard drive

and replace as needed.

The cables do not meet the

UDMA standards.

Only use the cables provided

by Kanguru Solutions with the

KanguruClone.

Troubleshooting