beautypg.com

Ivoclar Vivadent Metal-Zirconia Primer User Manual

Page 2

background image

Sandblast the restoration surface (sandblasting
parameters according to the instructions of the
manufacturer of the restorative material).

If necessary, clean the restoration in an ultrasonic
unit for about 1 minute.

Thoroughly rinse with water spray and dry with oil-
free air.

IMPORTANT! In order to create a strong bond, do
not clean the oxide ceramic surfaces with phosphoric
acid.

1.1.2 Metal or metal-supported restorations

Sandblast the restoration surface (sandblasting para-
meters according to the instructions of the manufac-
turer of the restorative material) until an even, matt
or non-glossy surface has been achieved.

If necessary, clean the restoration in an ultrasonic
unit for about 1 minute.

Thoroughly rinse with water spray and dry with oil-
free air.

IMPORTANT! In order to create a strong bond, do
not clean the metal surfaces with phosphoric acid.

1.2

Apply Metal/Zirconia Primer with a brush or a micro-
brush to the pre-treated surfaces. Allow the material
to react for 180 seconds. Disperse with a strong
stream of air.

1.3

Apply the luting composite (e.g. Multilink N) accord-
ing to the respective Instructions for Use and insert
the restoration.

Special notes
– Contamination with saliva, blood or water must absolute-

ly be avoided during the entire procedure. In case of con-
tamination, the entire treatment of the restoration is to
be repeated (see section 1).

– If the primer dries out on the surface of the restoration

before blasting with a strong stream of air, the surface
needs to be rinsed with pure alcohol and blown with air.

– Do not insert the brush into the Metal/Zirconia Primer

bottle. This may lead to contamination.

– Carefully close the Metal/Zirconia Primer bottle immedi-

ately after use.

Warning
– Flammable
– The product contains flammable organic solvents. Keep

away from ignition sources.

– Metal/Zirconia Primer is an irritant. Avoid contact with the

skin and mucous membrane. If the material should acci-
dentally come in contact with the skin, immediately wash
with copious amounts of water.

– In rare cases, contact with the skin may lead to sensitiza-

tion towards the ingredients.

– Commercial medical gloves do not provide protection

against the sensitizing effect of methacrylates.

Storage
– Metal/Zirconia Primer should never be used after the

expiration date.

– Storage temperature: 2–8 °C / 36–46 °F.
– Shelf life: see expiry date on label.

Keep out of the reach of children.
For use in dentistry only.

Date information prepared: 12/2009, Rev. 0

Manufacturer
Ivoclar Vivadent AG
FL-9494 Schaan / Liechtenstein

The material has been developed solely for use in dentistry. Processing should be carried out
strictly according to the Instructions for Use. Liability cannot be accepted for damages result-
ing from failure to observe the Instructions for Use or the stipulated area of application. The
user is responsible for testing the products for their suitability and use for any purpose not
explicitly stated in the Instructions for Use.

The Material Safety Data Sheet is available online at
www.ivoclarvivadent.com