beautypg.com

Harken C7475 MKIII Jib Reefing & Furling User Manual

Page 4

background image

HEADSTAY CUT LENGTH

Subtract the following from the headstay length and cut the

stay at that point.

STRINGING CONNECTORS ON STAY

Make sure the trim cap is at the top and the correct number

of connectors are used. The long bottom connector must be

slid on the rod last.

ROD COLDHEAD HEIGHT

Make sure the length of coldhead does not interfere with the

drive pin.

Distance between the collet bottom and the rollpin is 6.5 mm

HEADSTAY CUT LENGTH CHART

22.2 mm

25.4 mm

-30 rod (11.1 mm)

187 mm

-40 rod (12.7 mm)

201 mm

HEADST

AY CUT LENGTH

PREPARATION

Headstay Length

4

Nautor Furling

December 2004

6.5 mm

Clevis Pin Size

This manual is related to the following products: