T-10

A. 5

Speed Calibration, Decimal Place – This sets the decimal place location for the speed
display. The variable settings range between no decimal places and two decimal
places.

A. 6

Calibration Units – This sets the units of calibration for the speed display. The variable
settings offer either; inches per minute (Inc); or centimetres per minute (CEn); or non-
specific (rAd). When the closed loop tach feedback is connected and; if the inches per
minute option is selected the IPM L.E.D. will illuminate; or if the centimetres per minute
option is selected the CM/MIN L.E.D. will illuminate; or if the non-specific option is
selected neither the IPM nor the CM/MIN L.E.D.’s will illuminate.

A. 7

Braking – This sets the level of motor braking from instant braking to a variable degree
of pulsed graduated braking. The variable value range is from a reference value of 000
to 010 in increments of 1. A reference value of 0 provides instant braking whereas a
reference value of 10 provides the slowest, softest pulse braking.

A. 8

Response Gain – This sets the speed correction response rate. By having the motor
speed correction rate at a slow response, the motor takes longer to accelerate to speed
and reacts to motor speed variances slower. By having a fast response, the motor will
accelerate to speed quickly, sometimes resulting in over shooting of the preset speed,
and reacting to motor speed variances instantly, sometimes resulting in slight speed
oscillation. The variable value range is from a reference value of 001 to 010 in
increments of 1. A reference value of 1 provides the fastest speed correction rate,
whereas a reference value of 10 provides the slowest, speed correction response rate.

A. 9

Maximum Speed Scale – This sets the maximum speed at which the motor control will
allow (the speed is capped at this set percentage). The variable value range is from 001
to 100 percent of full speed, in increments of 1%.

A. 10 Program Select – This allows the operator to set the product/application specific

program. Programs will be shown as “-1” for example. Each GSP-2100 control will have
a number of preloaded programs to choose from depending on the application. Other
programs can be loaded by your local authorized Gullco service representative.

Note: Following the A.10 motor control variable parameter, U.1, U.2 & U.3 will follow as the
next three parameters. These are for factory diagnostic purposes only and are non-adjustable.
They indicate the revision level of software and hardware of the control.