Question:

How do I replace a 4-tone gong signal by a 3-tone gong? In accordance to the factory presets,

the trigger is connected to the control input B3 and it should stay that way.

Solution:

Performing the following changes is only possible for user 3!

The sequence S 25 which initiates the 4-tone gong signal G 20 is being started using the input B3.

The selected 4-tone gong signal G 20 has to be changed to the 3-tone gong signal G21 by
altering line 9 of sequence S 25 (see also on page 39). After selecting an unused user program

memory number (e. g. S 05), the displayed question “store?” has to be answered with “yes” to
store the new settings. Select the trigger B3 in the “trigger” menu and change the start sequence

from S 25 to S 05. Using the soft key “set” activates the new trigger setting.

Question:

I would like to use the start/stop function of the factory presets S 28, S 30 for playback and

remote recording of the message M 02 ( see also on page 36, 40/41). My installation should
include the inputs B3 and B4 instead of the inputs C3 and C4 reserved in the preset.

The indication lamps are not needed which makes retrofitting the port C not necessary.

Solution:

Performing the following changes is only possible for user 3!

For when the indication signals are not needed, the steps of the sequences S 28 (play message

M 02) and S 30 (record M 02) stay unaltered. Only the button C4’s stop operation is altered into
B4 in the sequence S 30. The new setting is re-stored under S 30. The trigger B3 is selected in

the “trigger” menu and the start sequence is changed from S 25 into S 28. Confirming the soft
key “set” activates this new setting (play M 02). Now, you have to select the trigger B4 and

change the start sequence S 26 into S 30. Afterwards confirm your settings (record M 02)

using the soft key “set”.