List of available gong parameters

Type four-stroke, three-stroke

bar1:

first gong stroke, A highest sound, B, C, to D deepest sound

attack1:

attack rate from 00ms (hard) to 99ms (soft)

release1:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

start 2:

start delay of the second gong stroke in seconds. (min 00.0s, max 99.9s)

bar2:

second gong stroke, A highest sound, B, C, to D deepest sound

attack2:

attack rate from 00ms (hard) to 99ms (soft)

release2:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

start 3:

start delay between second and third gong stroke in seconds. (min 00.0s, max 99.9s)

bar3:

third gong stroke, A highest sound, B, C, to D deepest sound

attack3:

attack rate from 00ms (hard) to 99ms (soft)

release3:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

start 4:

start delay between third and fourth gong stroke in seconds. (min 00.0s, max 99.9s)

bar4:

fourth gong stroke, A highest sound, B, C, to D deepest sound

attack4:

attack rate from 00ms (hard) to 99ms (soft)

release4:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

Type two-stroke, one-stroke

bar1:

first gong stroke, A highest sound, B, C, to D deepest sound

attack1:

attack rate from 00ms (hard) to 99ms (soft)

release1:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

start 2:

start delay of the second gong stroke in seconds. (min 00.0s, max 99.9s)

bar2:

second gong stroke, A highest sound, B, C, to D deepest sound

attack2:

attack rate from 00ms (hard) to 99ms (soft)

release2:

fading sound from XXL (long, several seconds.), XL, L, M, S, XS, XXS (short, approx. 1sec)

repetition:

number of repetitions of the gong sequence (min 1x, max 9999x), 0000 corresponds to
infinite repetition.

rep-del:

time between two gong sequences in seconds (min 00.1s, max 99.9s).

Remarks regarding parameter setting:

Although the above mentioned parameters are extensively variable, the gained results not always
represent a good sound. E. g.: attacks for low frequency bar strokes are acoustically quite different from
the gong A sound.

Since a maximum of 2 gong strokes can be simultaneously processed, starting the third gong too early
will abruptly end the first one and lead to unpleasant sound cut-off knacks. Effects like these resulting
from extreme parameter settings are of physical reason and should be optimized by listening tests, first.

16