String length meter operation – GAMMA 5800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 6 - July 2014) User Manual
Page 22
![background image](https://www.manualsdir.com/files/787176/content/doc022.png)
22
When the end of the string exits through the
hole on the right, press the ENTER button
to “Zero” the meter, and the length of string
will be measured from the point on the string
located at the edge of the exit hole. Pull the
end of the string at a slow steady rate and the
SLM will begin measuring the length of string
as it is pulled through the SLM and indicate
the measurement on the display. When the
desired length of string is measured, cut the
string at the edge of the exit hole.
NOTE:
When reaching the end of a string, pull the string through the SLM slowly to
avoid inaccurate measurement.
The measurement accuracy of the SLM is approximately +/- 0.5% of the indicated value
for thicker strings when the tension is set for 35 lbs and higher and badminton strings
when the tension is set for under 35 lbs prior to measurement.
STRING LENGTH METER OPERATION
String Length Meter
Press the String Length Meter (SLM) button
to enable the SLM function and display the
SLM screen. To change the measurement
units from Feet (FT) and meters (M) press
the SLM button to toggle between FT and M.
To measure a length of string from a reel
or set of string, insert the end of the string
through the loop from the backside of the
string guide attached to the front of the SLM.
Lift the clamp pad and insert the string through
the entry hole on the face plate of the SLM.
Continue to feed the string into the entry
hole until it exits the SLM through the hole
on the right side and release the clamp pad.
(In addition to aligning the strings with the
entry to the SLM, the felt clamp pads apply
a slight amount of pressure to the string and
wipe down the surface of the string to prevent
debris from entering the SLM).
NOTE:
When measuring thin strings such as badminton strings, apply light fi nger pres-
sure to the clamp pad to provide some back pressure while pulling the string through
the meter to prevent slipping and obtain more accurate measurements.
- 8800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 6 - July 2014) 8800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 9 - July 2014) 5800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 5B - March 2014) 5800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 5B - March 2014) 5800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 7 - June 2014) 5800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 6 - June 2014) 8800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 5B - March 2014) 5800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 6B - March 2014) 8800 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 8B - March 2014)