beautypg.com

Machine functions – GAMMA 5800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 6 - July 2014) User Manual

Page 16

background image

16

Knot String Function

The Knot String function is used to increase

the applied tension by a set percentage over

the tension setting on the last main string

or cross string pulled before tying of f. This

function helps to compensate for tension loss

caused by the slack portion of the string from

the string clamp to the tie-off knot.
Pressing the KNOT button will toggle the

Knot function on and off. When the Knot function is enabled, the Knot Icon will appear on the

Stringing Screen and the Blue LED will illuminate next to the KNOT button. The function will

be enabled for the next pull and then will automatically disable itself.

Setting the Knot Tension from the
Stringing Screen

To change the Knot Setting while in the

Stringing Screen, press the KNOT button

once and while the Knot Icon is visible on

the display, press and hold the Knot button

again until the Knot Setting is highlighted

above the Knot Icon. Press any of the F2,

F3 or F4 keys to increase the Knot Setting

in 1% increments and any of the F6, F7 or F8 keys to decrease the Knot Setting in 1% incre-

ments. When the desired Knot Setting is displayed, press ENTER to save the Knot Setting

for the active Memory Setting.

NOTE: Selectable Knot Settings range from 0% to 30% in 1% increments.

Setting the Knot Tension from the
Setting Screen

To change the Knot Setting from the Settings

Screen, press F1 to display the Settings

Screen. After the Settings Screen appears

on the display, press the KNOT button to

highlight the Knot Setting above the Knot

Icon. Press any of the F2, F3 or F4 keys to

increase the Knot Setting in 1% increments

and any of the F6, F7 or F8 keys to decrease the Knot Setting in 1% increments. When the

desired Knot Setting is displayed, press ENTER to accept and save the Knot Setting for the

active Memory Setting. If no other buttons are pressed within 10 seconds the display will

return to the Stringing Screen. Pressing the ESC or RETURN button will immediately return

to the Stringing Screen.

MACHINE FUNCTIONS