beautypg.com

GAI-Tronics MI05-101 Merge / Isolate Cabinet with External Option User Manual

Page 21

background image

Pub. MI05-101iom.2

Model MI05-101 Merge/Isolate Cabinet

Page: 21 of 24

\\86h27g1-fs\iomdocs\opnotes -- released\mi05-00x merge-isolate cabs\mi05-101.dir\mi05-101iom2.doc
01/09

Model GTK99019 Audio Interface

1. Mount the Model GTK99019 Audio Interface in accordance with GAI-Tronics Pub. K99019iom,

which is packaged with the equipment.

2. Connect TB1 of the audio interface to the 120 V ac power source using 3-conductor, No. 14 AWG ac

power cable. Power requirements for this interface are 120 V ac, 50/60 Hz at 0.2 amperes.

3. Connect the audio interface to the Model MI05-101

Me

r

ge

/

I

s

ol

a

t

e

Ca

bi

ne

t

s

Ext

e

r

na

l

I

nt

e

r

f

a

c

e

PCBA as follows using a 4-pair, No. 18–20 AWG cable. Refer to Figure 5.

Function

Audio Interface

Terminals

Connect

to

M/

I Cabinet’

s External

Interface PCBA

Page Line

TB2-4 and TB2-5

TB2-1 and TB2-2

Party Line

TB2-6 and TB2-7

TB2-3 and TB2-4

All-Call Control Lines

TB2-14 and TB2-15

TB2-7 and TB2-8

Page Override Control Lines

TB2-16 and TB2-17

TB2-5 and TB2-6

Figure 5. Model GTK99019 Audio Interface Connection Diagram