Inputs Screen
1. Inputs 1–7 must have the
Continuous Audio Message
box selected. This allows the message to
play while the input is active and stop when the input is inactive. Input control lines are supplied
from the M/I cabinet’
sExternal Interface PCBA. A reset input to the AMI is not required. See
screen shot below for example of Input 1. Duplicate these settings for inputs 2–7.
2. Change the
Current Output Combination
to
None
. This will prevent the AMI aux output 1 from
activating during alarm. This output should only activate during a telephone page (if applicable).