GAI-Tronics ICS Zone 2/22 Weatherproof Page/Party Station User Manual
Page 34

Pub. 42004-734L2D
ICS Zone 2/22 Weatherproof Page/Party
®
Station
Page 32 of 33
f:\standard ioms - current release\42004 instr. manuals\42004-734l2d.doc
11/14
70V/100V Speaker Output Option Specifications
Maximum output ............................................................................................................................... 24 watts
Nominal output voltage .............................................................................................. 70.7 volts or 100 volts
Environmental
Temperature range (operation and storage) ............................................ −22º F to 158º F (−30º C to 70º C)
Humidity ...................................................................................................................... 95% non-condensing
Enclosure ............................................................................................................................................... IP 66
Approvals
CE Mark
Certificate No.
Notified Body ID No. 0539
UL
International
DEMKO
A/S
Lyskear 8
DL-2730 Herlev
Denmark
DEMKO 10 ATEX 1010664x ..................... II 3 G Ex ic nA IIC T4 Gc and II 3 D Ex ic tb IIIC T135ºC Dc
IECEx UL 10.0038x ......................................................... Ex ic nA IIC T4 Gc and Ex ic tb IIIC T135ºC Dc
Typical Continuous Speaker Output Power Derating
1kHz Sinewave into a 8-ohm Load
0
5
10
15
20
25
30
0.1
1
10
100
Minutes
Wa
tt
s
-30°C
25°C
40°C
50°C
60°C
70°C
Figure 22. Typical Continuous Speaker Output Power Derating
1 kHz Sine Wave into an 8-ohm Load