Flowserve MX HART Field Unit User Manual
Page 69

69
MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14
flowserve.com
Command
Response Code
No.
Description
Code
Class
Description
91
Read Trend Configuration
0
1-4
5
6
7-10
11
12-127
Success
N/A
Error
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
Undefined
Invalid Trend Number
Undefined
92
Write Trend Configuration
0
1
2
3
4
5
6
7
8
9-10
11
12-15
16
17
18-127
Success
N/A
Error
Error
Error
Error
Error
Error
Warning
N/A
Error
N/A
Error
Error
N/A
No Command-Specific Errors
Undefined
Invalid Selection
Passed Parameter Too Large (trend update period)
Passed Parameter Too Small (trend update period)
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Set to Nearest Possible Value (trend update period)
Undefined
Invalid Trend Number
Undefined
Access Restricted
Invalid Device Variable Index
Undefined
93
Read Trend
0
1-4
5
6
7
8
9-10
11
12-127
Success
N/A
Error
Error
N/A
Warning
N/A
Error
N/A
No Command-Specific Errors
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
Undefined
Trend not Active
Undefined
Invalid Trend Number
Undefined
95
Read Device Communications
Statistics
0
1-5
6
7-127
Success
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
103
Write Burst Period
0
1-4
5
6
7
8
9
10-15
16
17-31
32
33
34
35
36
37-127
Success
N/A
Error
Error
Error
Warning
Error
N/A
Error
N/A
Error
Error
Error
Error
Error
N/A
No Command-Specific Errors
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Update Times Adjusted
Invalid Burst Message
Undefined
Access Restricted
Undefined
Busy
DR Initiated
DR Running
DR Dead
DR Conflict
Undefined
104
Write Burst Trigger
0
1-2
3
4
5
6
7
8
9
10
11
12
13
14-15
16
17-31
32
33
34
35
36
37-127
Success
N/A
Error
Error
Error
Error
Error
Warning
Error
N/A
Error
Error
Error
N/A
Error
N/A
Error
Error
Error
Error
Error
N/A
No Command-Specific Errors
Undefined
Passed Parameter Too Large
Passed Parameter Too Small
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Burst Condition Conflict
Invalid Burst Message
Undefined
Invalid Device Variable Classification
Invalid Units Code
Invalid Burst Trigger Mode Selection
Undefined
Access Restricted
Undefined
Busy
DR Initiated
DR Running
DR Dead
DR Conflict
Undefined
105
Read Burst Mode Configuration
0
1-5
6
7-8
9
10-31
32
33-127
Success
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
Invalid Burst Message
Undefined
Busy
Undefined