beautypg.com

Flowserve MX HART Field Unit User Manual

Page 68

background image

MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14

68

Command

Response Code

No.

Description

Code

Class

Description

71

Lock Device

0

1-4

5

6

7-9

10

11

12-15

16

17-31

32

33

34

35

36

37-127

Success

N/A

Error

Error

N/A

Error

Error

N/A

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Invalid Lock Code

Cannot Lock Device

Undefined

Access Restricted

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

76

Read Lock Device State

0

1-5

6

7-15

16

17-31

32

33-127

Success

N/A

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

Access Restricted

Undefined

Busy

Undefined

78

Read Aggregated Commands

0

1

2

3-4

5

6

7

8

9

10-29

30

31

32

33

34

35

36

37-127

Success

N/A

Error

N/A

Error

Error

N/A

Warning

Error

N/A

Warning

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Update Failure

Invalid Command Request

Undefined

Command Response Truncated – One or more commands are

dropped in the response

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

79

Command 79 Write Device

Variable

0

1

2

3-4

5

6

7

8

9

10

11-13

14

15

16

17

18

19

20-31

32

33

34

35

36

37-127

Success

N/A

Error

N/A

Error

Error

Error

Warning

N/A

Error

N/A

Warning

N/A

Error

Error

Error

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Device Family Status Bits Not Set

Undefined

Invalid Write Device Variable Command Code

Undefined

Requested value was returned in command response but Rate-of-

Change limit was exceeded. Device Variable Tracking to value written

at maximum rate allowed.

Undefined

Access Restricted

Invalid Device Variable Index

Invalid Units Code

Device Variable Index not allowed for this command

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

89

Set Real Time Clock

0

1

2

3

4

5

6

7

8-15

16

17-127

Success

N/A

Error

Error

N/A

Error

Error

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection (Time-set code)

Passed Parameter Too Large

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Undefined

Access Restricted

Undefined

90

Read Real Time Clock

0

1-5

6

7-127

Success

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

This manual is related to the following products: