Flowserve MX HART Field Unit User Manual
Page 64

MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14
64
Command
Response Code
No.
Description
Code
Class
Description
35
Write Primary Variable Range
Values
0
1
2
3-4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19-28
29
30-31
32
33-127
Success
N/A
Error
N/A
Error
Error
Error
Warning
Error
Error
Error
Error
Error
Warning
N/A
Error
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Invalid Selection
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Set to Nearest Possible Value (Upper or Lower Range Pushed)
Lower Range Value Too High
Lower Range Value Too Low
Upper Range Value Too High
Upper Range Value Too Low
Upper and Lower Range Values Out of Limits
Span Too Small (Device Accuracy May be Impaired)
Undefined
Access Restricted
Undefined
Invalid Units Code
Undefined
Invalid Span
Undefined
Busy
Undefined
36
Set Primary Variable Upper
Range Value
0
1-5
6
7
8
9
10
11-13
14
15
16
17-28
29
30-31
32
33-127
Success
N/A
Error
Error
Warning
Error
Error
N/A
Warning
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
In Write Protect Mode
Set To Nearest Possible Value (Upper Range Value Pushed)
Applied Process Too High
Applied Process Too Low
Undefined
Span Too Small (Device Accuracy May be Impaired)
Undefined
Access Restricted
Undefined
Invalid Span
Undefined
Busy
Undefined
37
Set Primary Variable Lower
Range Value
0
1-5
6
7
8
9
10
11-13
14
15
16
17-28
29
30-31
32
33-127
Success
N/A
Error
Error
N/A
Error
Error
N/A
Warning
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
In Write Protect Mode
Undefined
Applied Process Too High
Applied Process Too Low
Undefined
New Lower Range Value Pushed
Undefined
Access Restricted
Undefined
Invalid Span
Undefined
Busy
Undefined
40
Enter/Exit Fixed Current Mode
0
1-2
3
4
5
6
7
8-10
11
12-15
16
17-31
32
33-127
Success
N/A
Error
Error
Error
Error
Error
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Passed Parameter Too Large
Passed Parameter Too Small
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Undefined
Loop Current Not Active (Device in Multi-drop Mode)
Undefined
Access Restricted
Undefined
Busy
Undefined
41
Perform Self Test
0
1-5
6
7-15
16
17-31
32
33-127
Success
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
Access Restricted
Undefined
Busy
Undefined
42
Perform Device Reset
0
1-5
6
7-15
16
17-31
32
33-127
Success
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
Access Restricted
Undefined
Busy