Flowserve MX HART Field Unit User Manual
Page 65

65
MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14
flowserve.com
Command
Response Code
No.
Description
Code
Class
Description
45
Trim Loop Current Zero
0
1-2
3
4
5
6
7
8
9
10
11
12-15
16
17-31
32
33-127
Success
N/A
Error
Error
Error
Error
Error
N/A
Error
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Passed Parameter Too Large
Passed Parameter Too Small
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Undefined
Incorrect Loop Current Mode or Value
Undefined
Loop Current Not Active (Device in Multi-drop Mode)
Undefined
Access Restricted
Undefined
Busy
Undefined
49
Write Primary Variable
Transducer Serial Number
0
1-4
5
6
7
8-15
16
17-31
32
33-127
Success
N/A
Error
Error
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Undefined
Access Restricted
Undefined
Busy
Undefined