Page 16 of 44

flowserve.com

When fitted with a sight glass, fill the bearing housing
with oil by unscrewing the oil filler/breather and fill
through the hole.

Grease lubricated pumps and electric motors are
supplied pre-greased. To regrease, remove the pipe
plug from both the inboard and outboard bearing
location. Apply grease through the grease nipples until
it comes out of the vent holes then reinstall the pipe
plugs. Do not over grease. Grease lubricated sealed
bearings do not require relubrication and should be
replaced on a regular maintenance scheme.

Other drivers and gearboxes, if appropriate, should
be lubricated in accordance with their manuals.


5.2 Pump lubricants


5.2.1 Recommended oil lubricants

Oil

Splash / force feed / purge oil mist lubrication

Viscosity cSt

@ 40 ºC

32

46

68

Oil temperature range *

-5 to 65 ºC

(23 to 149 ºF)

-5 to 78 ºC

(23 to 172 ºF)

-5 to 80 ºC

(23 to 176 ºF)

C

e

n

tr

if

u

g

a

l

p

u

m

p

lu

b

ri

c

a

ti

o

n

Designation to ISO 3448

and DIN51524 part 2

ISO VG 32

32 HLP

ISO VG 46

46 HLP

ISO VG 68

68 HLP

BP Castrol

Energol HLP-HM 32

Energol HLP-HM 46

Energol HLP-HM 68

ESSO

NUTO HP 32

NUTO HP 46

NUTO HP 68

ELF/Total

ELFOLNA DS 32

Azolla ZS 32

ELFOLNA DS 46

Azolla ZS 46

ELFOLNA DS 68

Azolla ZS 68

LSC (for oil mist)

LSO 32 (Synthetic oil)

LSO 46 (Synthetic oil)

LSO 68 (Synthetic oil)

ExxonMobil

Mobil DTE 24

Mobil DTE 25

Mobil DTE 26

Q8

Q8 Haydn 32

Q8 Haydn 46

Q8 Haydn 68

Shell

Shell Tellus 32

Shell Tellus 46

Shell Tellus 68

Chevron Texaco

Rando HD 32

Rando HD 46

Rando HD 68

Wintershall (BASF Group)

Wiolan HS32

Wiolan HS46

Wiolan HS68

O

il

c

o

m

p

a

n

ie

s

a

n

d

lu

b

ri

c

a

n

ts

Fuchs

Renolin CL 32

Renolin CL 46

Renolin CL 68

* Note that it normally takes 2 hours for bearing temperature to stabilize and the final temperature will depend on the ambient, r/min, pumpage
temperature and pump size. Also some oils have a greater viscosity index than the minimum acceptable of 95 (eg Mobil DTE13M) which may
extend the minimum temperature capability of the oil. Always check the grade capability where the ambient is less than -5 ºC (23 ºF).

Use LSC for oil mist. Oil parameters provide flash point >166 ºC (331 ºF), density >0.87 @ 15 ºC (59 ºF), pour point of -10 ºC (14 ºF) or lower.


5.2.2 Bearing sizes and capacities

Medium duty

oil bearings

Regreasable

bearings

Sealed grease

bearings

Optional oil

bearings

Inboard end

Outboard end

Inboard end

Outboard end

Inboard end

Outboard end

Outboard end

Frame

size

Ball

bearing

Double row

angular contact

Ball

bearing

Double row

angular contact

Ball bearing

metallic shields

Double row

angular contact

Duplex back-

to-back AC

Approx

oil

capacity

litre

(fl.oz)

A
B
C
D

6307 C3
6309 C3

6311 C3

6315 C3

3307 A C3
3309 A C3
3311 A C3
3314 A C3

6307 C3 Z
6309 C3 Z

6311 C3 Z

6315 C3 Z

3307 A C3 Z
3309 A C3 Z
3311 A C3 Z
3314 A C3 Z

6307 C3 2Z
6309 C3 2Z
6311 C3 2Z
6515 C3 2Z

3307A C3 2Z
3309A C3 2Z

3311A C3 2Z

3314A C3 2Z

7307
7309
7311
7314

0.25 (8.5)
0.5 (16.9)
0.6 (20.3)
1.8 (60.9)

Note: The bearing sizes do not constitute a purchasing specification.
'A' in the double row angular contact bearing nomenclature defines the requirement of no filling slot.
Duplex back-to-back bearings at drive end may be required depending upon operating conditions and pump model.