Flowserve WUC Worthington User Manual
Page 16

WUC USER INSTRUCTIONS ENGLISH - 07/14
Page 16 of 52
2) Mount a clamp to the column pipe. The clamp
has lifting lugs, which allow to use a crane for
lowering this assembly into the pit (see picture).
3) Connect the next line shaft (refer to section 6,
Maintenance) and put on the next rising main
column pipes [1350.2] (see picture) by using a
second clamp.
4) Now the assembly consists of the hydraulic
section and two column sections. This assembly
is taken by a crane using the second clamp.
5) Take off the first clamp and lowering down the
assembly until the clamp is supported by the
wooden frame (see picture).
Repeat step 1 to 5 until the pump is completely
assembled.