beautypg.com

Flowserve WUC Worthington User Manual

Page 16

background image

WUC USER INSTRUCTIONS ENGLISH - 07/14

Page 16 of 52

2) Mount a clamp to the column pipe. The clamp

has lifting lugs, which allow to use a crane for
lowering this assembly into the pit (see picture).



3) Connect the next line shaft (refer to section 6,

Maintenance) and put on the next rising main
column pipes [1350.2] (see picture) by using a
second clamp.

4) Now the assembly consists of the hydraulic

section and two column sections. This assembly
is taken by a crane using the second clamp.

5) Take off the first clamp and lowering down the

assembly until the clamp is supported by the
wooden frame (see picture).


Repeat step 1 to 5 until the pump is completely
assembled.

clamp

1350.2

second clamp

This manual is related to the following products: