Fieldpiece SMAN4 - 4 Port Wireless Digital Manifold User Manual

Fieldpiece, Quick start, Certifications

background image

01

06

02

07

03

08

04

09

05

10

Pressure (bar)

Pressure (pounds/in

2

)

Pressure (kilopascals or Megapascals)

Negative Pressure (inches of mercury)

Negative Pressure (cm of mercury)

Subcooling

T2 Direct

Liquid Saturation Temperature

Outdoor Dry Bulb

Vacuum Stopwatch

Hours:Minutes or Minutes:Seconds

Battery Life

Connection Strength

Auto Power Off Enabled

Wireless Signal Lost

Selected Refrigerant of System

Quick Start

1 Power on your SMAN4 by holding the ON/

OFF button for 1 second.

2 Select desired units (English or Metric or a

combination) by holding ENTER for 1 second.

3 Connect hoses and pipe clamps to the system.

4 Press the circular button to select between

Actual Superheat and Subcooling, Target

Superheat, Direct Temperature Display (T1 T2

Direct) or Saturation Temperature Display.

Certifications

FCC ID: VEARF915

C-Tick (N22675)

CE

RoHS Compliant

Description

Your SMAN4 is the first true wireless-enabled

digital refrigerant 4-port manifold and vacuum

gauge for HVACR service. Use optional wireless

transmitters like SDP2 Dual In-Duct Psychrometer

to receive temperature measurements over-the-

air for real-time target superheat calculations.

Your SMAN4 can wirelessly send data to the HG3

HVAC Guide for more extensive analysis, data

logging, or printing reports for your customers.

Your SMAN4 combines high precision,

absolute pressure manifold gauges, a superheat/

subcooling calculator, true micron gauge for

vacuum, and dual temperature measurements

into one easy-to-use instrument. Your SMAN4

calculates and simultaneously displays target

superheat and actual superheat to verify

proper charging of a unit. Your SMAN4’s 4-port

manifold has a large 3/8” vacuum port and 3/8”

bore throughout the block for quicker recovery

and evacuations.

Your SMAN4 is designed to meet the demands

of the HVACR technician with a ruggedized

rubber boot for durability, a strong metal

hanger for easy storage and a form fitting, water

resistant, padded nylon pouch.

Pressure (bar)

Pressure (pounds/in

2

)

Pressure (kilopascals or Megapascals)

Negative Pressure (inches of mercury)

Negative Pressure (cm of mercury)

Superheat

T1 Direct

Vapor Saturation Temperature

Indoor Wet Bulb

Micron Reading Has Stabilized

Set Mode

Alarm Mode

High Alarm

Low Alarm

Vacuum (Microns of Mercury)

T1 thermocouple - T2 thermocouple

Target Superheat

Fieldpiece

4-Port Wireless

Manifold & Vacuum

Gauge

OPERATOR'S MANUAL

Model SMAN4

Controls

1 Insert Type K thermocouple plugs here.

2 Temperature calibration pots.

3 Press to zero atmospheric pressure.

4 Press to calibrate to refrigerant tank.

(See Advanced Pressure Calibration section.)

5 Press to turn on backlight. Hold when

powering on to toggle Auto Power Off.

6 Press/hold to cycle through refrigerants.

7 Hold 1 second to toggle power on/off.

8 Press up or down arrow to adjust values.

9 Press to confirm selection.

Hold 1 second to adjust units.

10 Press to turn on/off the Hi/Lo vacuum

alarms and hold to change alarm settings.

11 Press to toggle through temperature tests.

12 Hold 1 second to Sync to a wireless enabled partner device.

13 Turn clockwise to close High side port.

14 Turn clockwise to close Low side port.

15 Turn clockwise to close 3/8" Vacuum port.

16 Turn clockwise to close Refrigerant port.

Functions

Superheat and Subcooling

1 Press circular button to cycle through temperature modes until

SH and SC are shown. The SMAN4 can calculate and display both

superheat and subcooling simultaneously.

2 Select the appropriate refrigerant using the REFRIGERANT button.

3 Connect EPA approved refrigerant hoses to low and high side on

SMAN4. Plug Type K thermocouple pipe clamps into T1 and T2.

4 Connect your SMAN4 to the system:

Superheat: Hand tighten low side hose to suction line service

port. Place the T1 pipe clamp thermocouple on the suction line

between the evaporator and compressor, no closer than 6 inches

to compressor.

Subcooling: Hand tighten high side hose to liquid line service

port. Attach the T2 pipe clamp thermocouple on the liquid line

between the condenser and expansion valve (TXV), as close to the

service port as possible.

5 After turning the system on or making any adjustments to

the system wait 15 minutes before charging by superheat or

subcooling to ensure that the system is running normally.

6 To add or remove refrigerant connect a refrigerant or recovery

tank to the REF port on SMAN4. Follow charging or recovery

practices from manufacturer. Use the low side, high side, and REF

valves on SMAN4 to charge or recover refrigerant as needed. Let

system stabilize again for 15 minutes.

T1 T2 Direct

1 Press circular button until T1 and T2 are shown.

2 Plug in any Type K thermocouple into T1 and/or T2.

3 Read the temperature directly from the display.

4 T1-T2 is displayed in the lower left corner of the display.

Saturation

Shows vapor (VSAT) and liquid (LSAT) saturation temperatures

calculated from the pressures measured and the refrigerant selected.

Target Superheat

Target Superheat is only used for charging fixed orifice

air conditioning systems. Your SMAN4 allows you to receive
real-time indoor wet bulb (IDWB) and outdoor dry bulb
(ODDB) temperatures wirelessly to calculate target superheat.
These values can also be entered manually or input directly by
connecting the included wet and dry bulb thermocouples to T1
and T2 respectively.

Receive IDWB and ODDB temperatures wirelessly

1 Press circular button until you’ve entered Target SH mode.

2 Press UP or DOWN ARROW. IDWB icon will begin blinking.

3 Hold SYNC on SMAN4 until a beep is heard (>1 sec).

4 Attach an accessory head (like ARH5, ARH4, or AAT3) capable of

measuring indoor wet bulb temperature to a Fieldpiece wireless

transmitter (sold separately). Ready instrument to measure

indoor wet bulb temperature and place at the return of the

evaporator between the filter and the coil.

5 Select transmit mode on Fieldpiece wireless transmitter and hold

SYNC until wireless partner searching begins. For SDP2 Dual In-

Duct Psychrometer, power on and press SYNC button for 1 second.

Once SMAN4 is connected with transmitter, the real-time wet

bulb temperature measurement will display on SMAN4. The ODDB

icon will begin blinking.

6 Repeat steps 3 -5 for outdoor dry bulb measurements (ODDB). For

outdoor dry bulb measurement, place the accessory head onto

the side of the condenser. For accurate results, keep it shaded

from direct sunlight.

7 Real-time target superheat is calculated and located in lower

left corner of display when SMAN4 is receiving real-time indoor

wet bulb and outdoor dry bulb measurements from the wireless

devices.

Note: For real-time target superheat calculations, both IDWB and

ODDB measurements must be received wirelessly.

Note: When the IDWB or ODDB is wirelessly synced with SMAN4, and

the signal/sync is lost, “NSG” will display. The SMAN4 will try to

sync with partner device for 4 minutes while the unit is powered

ON. During these 4 minutes IDWB or ODDB can be synced

wirelessly to a different Fieldpiece transmitter but manual entry

or entry though thermocouple will be disabled.

Note: Retrieval of IDWB and ODDB wireless measurements will be

temporarily disabled for 30 seconds (nSG will display) if SMAN4

loses communication with HG3, the wireless tower ( ) will blink

and “nSG” will be displayed on SMAN4 until HG3 reconnects or

30 seconds has elapsed. At this time, IDWB and ODDB wireless

measurements will resume.

Input temperatures with Type K thermocouples

1 Press circular button until Target SH is shown on the bottom,

center of display.

2 Plug ATWB1 Wet bulb Type K thermocouple into T1 and ATA1 Dry

bulb Type K thermocouple into T2. Both included with SMAN4.

3 Press UP or DOWN ARROW to toggle between IDWB or ODDB

input. The icons will begin blinking. Press ENTER to select which

temperature you want to input first, either IDWB or ODDB. The

real-time temperature from the thermocouple will be displayed.

4 For IDWB input, wet the sock of the ATWB1. Clip it to the return

of the evaporator between the filter and coil. When the wet bulb

temperature reaches its lowest point and stabilizes, press ENTER

to lock the reading. If the inputted temperature is above or below

the wet bulb range, "OL" or “-OL” will blink and a beep will be

heard. Retake the measurement if this occurs.

5 For ODDB input, clip the ATA1 thermocouple to the side of the

condenser. Once reading is stable, press ENTER. If the inputted

temperature is above or below the dry bulb range, "OL" or “-OL”

will blink and a beep will be heard. Retake the measurement if

this occurs. For accurate results, keep the ATA1 shaded from direct

sunlight.

6 Once both IDWB and ODDB are locked in, the Target Superheat

will show in the lower left corner of the display. If the Target

Superheat calculated from the IDWB and ODDB temperatures is

outside the range in which air conditioning is recommended then

“OL” is displayed. Usually, raising the indoor temperature will

bring the conditions within manufacturer’s recommendations. If

your target superheat is out of the recommended range, re-take

your measurements.

7 To re-take either IDWB or ODDB, press UP or DOWN ARROW until

the icon (IDWB or ODDB) you wish to re-take is blinking. Press

ENTER. Re-do the measurement and press ENTER to lock it in. The

newly calculated target superheat will be displayed.

Input temperatures manually

1 Press circular button until Target SH is shown at the bottom,

center of display. Unplug thermocouples from T1 and/or T2.

2 Press UP or DOWN ARROW to toggle between IDWB or ODDB

input. The icons will begin blinking. Press ENTER to select which

temperature you want to input first, either IDWB or ODDB. The far

left digit of IDWB or ODDB will begin blinking indicating manual

input mode is ready.

3 Press the UP or DOWN ARROW to change values and press ENTER

to lock in each digit. Once the last digit for ODDB or IDWB is

locked in, the calculated target superheat will show in the lower

left corner of the display.

Note: When pressing ENTER to lock in the last digit for IDWB or

ODDB, if the inputted temperature is below or above the wet bulb

or dry bulb range, "OL" or “-OL” will flash once and a beep will be

heard. In both instances you must re-input the measurement.

1

1

2

2

3