ST300 SETUP



Press Softkey beneath ClearCues to clear all Cue Points to 00:00:00:00.
Press Softkey [YES] when asked “Are You Sure?”

Press Softkey beneath SetDefault to set ST300 to default settings.
Press Softkey [YES] when asked “Are You Sure?”

DISPLAY

SOFTWARE

VERSION

The version number for the currently installed software is displayed.

VIDEO

STANDARD

Press Softkey to select NTSC, PAL, or 24P video standard, depending on the standard
you’re using.

INPUT VIDEO

DELAY

Input Video Delay specifies the time interval between video recorded on the Recorder part
of the DSR being available for playback.
This parameter is used in GO TO LIVE function.
The default value is 5 seconds.

REFERENCE

VIDEO

Press softkey to Enable/Disable Reference Video.

MARK-Q

Press Softkey to:
Enable ADVANCE to next Cue Point, when [MARK] is pressed.
OR
Maintain CURRENT Cue Point when [MARK] is pressed.

DROP

FRAME

Press Softkey to select DROP FRAME ON or OFF.
Used to preset the VTR’s Timecode Generator.

SEG DURATION

Enter SEG duration that will be used to calculate IN (OUT) point.

AUTO MARK

Press softkey to turn AUTO MARK ON/OFF.
AUTO MARK allows one-key marking of segments.

TRANSMIT

CUELIST

Transmits Cuelist to another ST300 or to a PC.

RECEIVE

CUELIST

Receives Cuelist from another ST300 or a PC.