background image

The Analyst RS422/RS232 Tester

Page 21 of 27

c.

The computer will recognize The Analyst as a removable hard disk drive.
Use Windows Explorer to view the files in this removable drive.

d.

Copy files from The Analyst to the computer the same way that you would
copy files from one hard drive to another.

e.

Use Windows’ “Unplug or Eject Hardware” function to safely disconnect
The Analyst from the computer.

f.

Press the [EXIT] key on The Analyst to exit UPLOAD mode.

g.

Run the supplied Analyst File Converter Tool software application on our
computer to format the log files as text files that Excel and text programs
can read.

G4. Erase Log Files/Initialize Log Files

a.

From the LOG MENU, press the [ERASE] key.

b.

Press [OKAY] to continue, or press [EXIT] to abort.

c.

When the erase process is completed, the LOG MENU will be displayed.