beautypg.com

DNF Controls Analyst, RS422/RS232 Tester With (LOG 1) SR Data Logging Option User Manual

Page 16

background image

Page 12 of 27

The Analyst RS422/RS232 Tester

MONITOR Screen- RS232

DIR

ÎÎ

Affect data communication path from IN port to OUT port

IN

Î ÎÎ communication from Controller to Device

RS232

ÍÍ communication from Device to Controller

RTS

Open

RxTx

Norm

Dir

ÎÎ

More

Exit

MON.

Disp

Run

Sw #1

Sw #2

Sw #3

Sw #4

Sw #5

Sw #6

Sw #7

Sw #8

DIR

ÍÍ

Affect data communication path from OUT port to IN port

Í OUT ÎÎ communication from Controller to Device

RS232

ÍÍ communication from Device to Controller

RTS

Open

Dir

ÍÍ

More

Exit

MON.

Disp

Run

RxTx

Norm

Sw #1

Sw #2

Sw #3

Sw #4

Sw #5

Sw #6

Sw #7

Sw #8

[RTS] Connect IN port RTS to IN port CTS. Disconnect OUT CTS from IN CTS.

Connect IN port DTR to IN port DSR. Disconnect OUT DSR from IN DSR.

[RxTx] Swap transmit and receive lines

[Dir]

Affect data communication path from IN port to OUT port (

ÎÎ)

Or, affect data communication path from OUT port to IN port (

ÍÍ)

[More] Select More screen

[Exit]

Exit Monitor Mode

[Disp] Display mode-

Run: Update display with received data.

Pause: Do not update display with received data.

[Top]

Jump to beginning of received data.

[End]

Jump to end of received data.

Current byte number is displayed on the right side of the screen on the
third line.

This manual is related to the following products: