The Analyst RS422/RS232 Tester

F.

Monitor Serial Communication Between Equipment

Use MONITOR Mode to monitor serial communication between two pieces of equipment.

1)

From the MAIN Screen, press the [MENU] key.

2)

Press the [IN] and [OUT] keys to toggle between RS422 and RS232. Select
either RS422 or RS232 to match the equipment being monitored.

3)

Press the [Exit] key to exit the MENU Screen.

4)

Press the [MON] key to select MONITOR Mode.

5)

Connect The Analyst RS422/RS232 Tester between the two pieces of equipment.

(Shown- IN RS422, OUT RS422)