Trigger, Grass valley group, Sony – DNF Controls 2034CL-MAV-PBIO User Manual
Page 10

1
1
0
0
2034CL-MAV-PBIO
8. TRIGGER
The operator fires a trigger using the Timeline or Run function on the production switcher. The
ST300 puts the Video Server into the following modes based on the trigger value:
GRASS VALLEY GROUP
Trigger Value Mode
0
Play
1
Recue to beginning of clip
2
Slo-mo
using
ST300
Preset
Speed
3
Reverse
Play
4
Still
Frame
5
None
6 or greater
Play
SONY
Trigger Value Mode
0
Recue to beginning of clip Play
1
Play
2
Slo-mo
using
ST300
Preset
Speed
3
Reverse
Play
4
Still
Frame
5
None
6 or greater
Play
To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR
GANG the required VTRs on the ST300. See the Menu Table for GANG instructions. Enable the
Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to the enabled
VTR. The other VTRs in the GANG will perform the same action.