Page 3
The pilot wire principle enables the required operating mode
for the heating element to be selected from the programming
control unit.
The corresponding temperature is set directly by the heating
element thermostat (room by room control).
• Heating Programming
- 1 customizable program per day and per zone
- Automatic mode override:
It is possible to use a different operating mode (Comfort,
Economy, etc.) from the current one, until the next change
of program
- Absence: Constant or timed (from 1 to 99 days) to set
the installation to frost protection mode
• Transmission by power line carrier
- No damage to the existing installation
- Use with pilot wire receivers of the X2D PLC range
- Compatible with an energy manager
(e.g. GECPL1, GP4 CPL)
- Upgradeable system
• Tariff Management
- Linked with a CPL X2D energy manager (e.g. GECPL1
or GP4 CPL), it can reduce your energy consumption
according to the current tariff period
- Compatibility with all tariffs
• Radio Option
- DRIVER CPL is compatible with the TYDOM 520 radio
module that is used to associate domotics functions:
door/window magnetic contact, alarm control unit, etc.
- 5 -
- 4 -
The Pilot Wire
Time Setting
Description
Pre
ss
and relea
s
e:
s
low forw
a
rd.
Pre
ss
and hold: f
as
t forw
a
rd.
Turn the
s
elector to
E
a
ch time yo
u
p
ass
0.00 yo
u
ch
a
nge the d
a
y
Command
s
ent by
the control unit
Corre
s
pondin
g
temperature
on the heatin
g
element
Comfort
Comfort
s
etting (thermo
s
t
a
t kno
b
)
Economy
Economy
s
etting or -2°C or -
3
°C in rel
a
tion
to the comfort
s
etting (
a
ccording to the model)
Fro
s
t Protection
Fro
s
t protection
s
et to 7°C or
8
°C
(depending on model)
or
Sh
u
tdown
He
a
ting
s
h
u
tdown