4-2 Maintenance
&
Troubleshooting
Tree Problems
Symptom/Condition
Possible Cause/Remedy
Tree does not light at all
•
Check power and fuse to tree
•
Check power to isolation interface
•
Check bottom left corner of screen for SLCK
•
If SLCK is there, check power to starter’s box
interface
•
Check SBI to see if 3 LED’s are lit, Trans and Rec
leads from SBI to isolation interface may be
switched
•
Check SBI Trans and Rec LED’s on isolation
interface
•
Check communications cable which transmits data
from C-44 to SLEB
Bulb in tree not lit
•
Change bulb
•
Check socket and wiring
•
Change driver board
Bulb in tree stays lit
•
Change driver board
Tree Flickers
•
Check Grounding wires in Start line Box
Printer Problems
Symptom/Condition
Possible cause/remedy
Printer not working
•
Check to see if printer is enabled at C-44
•
Check power and connectors
•
Check to see if printer select light is lit
If Log printer
•
Check communications cable which sends data to
log printer
If E.T. printer
•
Check time slip printer interface LED’s
•
Check E.T. printer data LED on isolation interface
•
Check E.T. printer fault LED on isolation interface
•
Check communications cable which sends data to
E.T. printer
Display Problems
Symptom/Condition
Possible Cause/Remedy
No display at scoreboards
•
Enabled in C-44 Configuration Menu?
•
Check power to isolation interface and displays
•
Check display transmitter board In C-44,
(Drawing A-55998) which sends data to displays
via isolation interface.
•
Check for + 12VDC on signal input of driver.
Dial-ins not showing
•
In the scoreboard enable mode, was a Y placed in
the dial-in?
•
Is the F5 key being depressed?