Daktronics C44 User Manual
Page 21

New Track
2-7
Installation
Isolation Interface to Starters Box Interface Wiring
*Isolation Interface Drawing A-56252
**Start Line Interface Drawing A-72242
Isolation Interface to Start Line J-Box
Description
From (I/I)*
Cable
Specification
Wire Color
To (SLJB)**
Function
TB7-1 Red
TB3-1
LPSTAGEPCL-P
TB7-2 Black
TB3-7
LPSTAGEPCL-N
Pre-Stage
Left Lane
TB7-3
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB7-4 Red
TB3-2
LSTAGEPCL-P
TB7-5 Black
TB3-7
LSTAGEPCL-N
Stage Left Lane
TB7-6
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB7-7 Red
TB3-3
LGUARDPCL-P
TB7-8 Black
TB3-7
LGUARDPCL-N
Guard Left Lane
TB7-9
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB1-1 Red
TB3-4
RPSTAGEPCL-P
TB1-2 Black
TB3-8
RPSTAGEPCL-N
Pre-Stage Right
Lane
TB1-3
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB1-4 Red
TB3-5
RSTAGEPCL-P
TB1-5 Black
TB3-8
RSTAGEPCL-N
Stage Right Lane
TB1-6
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB1-7 Red
TB3-6
RGUARDPCL-P
TB1-8 Black
TB3-8
RGUARDPCL-N
Guard Right Lane
TB1-9
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
TB16-1 Red
TB1-1
SIG3-P
TB16-2 Black
TB1-2
SIG3-N
Tree Signal
TB16-3
Beldon 8760
(Dak W-1117)
Shield No
Connection
Shield-N
Refer to the Operational Check (Section 2.8) for connection and power up procedure.
*Isolation Interface
**Start Line Junction Box
Note: If field cabling for guard beam photocells is present, but guard beam
photocells are not used, do not connect unused guard beam cabling to the isolation
interface terminal blocks (TB7-7, TB7-8, TB7-9, LGUARDPCL, and TB1-7, TB1-8,
TB1-9, RGUARDPCL).
Description
Form (I/I)*
Cable
Specifications
Wire Color
To (SLI)**
Function
TB 13-1
Red
Trans +
Rec-P
TB 13-2
Black
Trans -
Rec-N
TB 13-3
Shield
Not Connected
Earth
TB 13-4
Green
Rec +
Trans-P
TB 13-5
White
Rec -
Trans-N
Isolation Interface/
Start line Interface
Communications
TB 13-6
Manhattan u4473
(Dak W-1234)
N.C. Not