Location requirements – Daktronics C44 User Manual
Page 17

New Track
2-3
Installation
Infrared Photocells
Item
Part No.
#
Part No.
#
Part No.
#
Part No.
1 0A-1067-0128 11 W-1267
21 0A-1067-0108 31 Incl.
w/item
#28
2
Incl. w/item
#1
12 W-1117
22 0A-1067-0111 32 A-1157
3 A-1305
13
0A-1067-0099 23
0A-1067-0064 33
0A-1081-0016
4 A-1157
14
0A-1067-0100 24
0A-1067-0065 34
Custom
5 W-1239
15 W-1399
25 0A-1067-0063 35 Custom
6 0A-1067-0076 16 0A-1067-0010 26 W-1117
36 0A-1067-0143
7 W-1266
17
0A-1081-0146 27
0A-1067-0080 37
W-1117
8 W-1266
18 W-1237
28 0A-1067-0050 38 EC-1082
9 W-1264
19 0A-1067-0107 29 W-1350
39 A-1078
10 W-1267
20 0A-1067-0071 30 A-1305
40 Custom
2.6
Location Requirements
Reference Drawings:
Field Cabling; C-44 Timer ........................................................... Drawing B-75554
This section explains the equipment locations on the track for best operation. Such topics as
conduit, power and electrical requirements, noise levels, and other location considerations are
discussed. Daktronics recommends that these guidelines be followed as closely as possible.
Signal Conduit and Cable
All cable should be 18 awg twisted shielded pair, Beldon 8760 (Dak W-1117) unless
noted. All cable should be in conduit. Refer to Drawing B-75554 for conduit sizes and
cable types.
Power
The following is a list of electrical items and their respective power requirements.
Unit Power Requirement (Watts)
Start line outlet
100
Tower outlets
1800
C-44 console
100
Color monitor (C-44)
114
Isolation interface
30
Printer (log or time slip)
30
Time slip printer booth outlet
84
60 ft. line outlet
200
1/8th mile line outlet
30
Starters box interface
100
Color monitor (results)
102
DAKTRONICS 486DX computer
100
Three-amber tree
2000 (min 20 amps)