16

Maintenance & Troubleshooting

Control Enclosure Maintenance

Performing preventative maintenance will ensure proper air circulation to internal
components. How much maintenance is required depends on the surrounding environment.
The filter is on the inside bottom door panel. Remove the filter and clean with warm, soapy
water and dry gently. Check the filter for signs of damage such as tears, cuts, and excessive
war from the environment. If necessary, order a new filter (Hoffman

®

part number WFF1 –

visit

www.hoffmanonline.com

). Also, check the fan assembly and clean the blades with

compressed air.

5.2 Troubleshooting

This section lists potential problems with the system, indicates possible causes, and suggests
corrective action. This list does not include every possible problem, but it does represent
some of the more common situations that may occur. If the problem persists, please contact
Daktronics for assistance.

Note: Be sure to power on the announcer’s rack, fiber conversion box, and cabinet breakers.
Make sure all connections from source to the fiber conversion box are complete.

Symptom/Condition

Possible Cause

Potential Solution

No power to cabinet; green
indicator light is off on bottom of
control enclosure

Breaker is off at sign

Bad A-2238 power supply

Turn breaker ON

Order new power supply

No audio from cabinet, but
source (announcer

’s rack)

shows output

No power at cabinet

Fiber conversion box is
unplugged from wall outlet
or cable to announcer

’s

rack

Turn breaker on

Plug in fiber conversion box

No audio from cabinet

Fiber link down/
TX-RX swap

Fiber link down/
broken fiber

Swap TX-RX fibers to fix
link

Replace fiber splice, repair
fiber termination/cable

Weak audio from cabinet

Improper gain at Analog to
Digital Converter (in fiber
conversion box)

Adjust gain according to
Biamp Audia Input &
Output Expanders
Operation Manual
in
Appendix B