3.9 Optional Temperature Sensor Electrical Installation

Reference Drawing:

Schem, Sig Wiring, W/Quick Connect PCB ................ Drawing B-177662

After mounting the optional temperature sensor as described in Section 2.6 follow
these steps to complete the electrical installation.

Using the Quick Connect and 10 foot cable

1. The temperature sensor is provided with 10 feet

of weather resistant cable. The cable does not
need to be in conduit.

2. Route the cable to the display and connect the

Quick Connect to the Temp Sensor input on the
back of the first display (J31). Be sure to secure
any excess cable from be pulled loose in the wind.

Using the Quick Connect and less then the 10
foot cable

1. Disconnect the CAN temp sensor cable from the temperature sensor

terminal block in the CAN temp sensor housing. (0A-1151-0005)

2. Cut the cable to desired length and reattach to the temperature sensor

terminal block in the CAN temp sensor housing as follows:

Wire Color

Temp Sensor

Terminal Block (TB1)

Red

+5V CAN (Pin 1)

Green

CANH (Pin 2)

White

CANL (Pin 3)

Black

GND (Pin 4)

*Note: Do not terminate shield at this point.

Figure 35: CAN Temp Sensor Wiring

Electrical Installation