RS422 Interconnection

The Quick Connect cable is the most common method of terminating signal between
two displays. The ten-foot cable goes from the RS422 OUT on the first display to the
RS422 IN on the second display.

If the displays are not back-to-back, or
are too far apart for the quick connect
interconnect cable to reach, a 4-
conductor shielded cable of the correct
length is used. One end will connect at
the “RS422 OUT” 6-position controller
board terminal block (A31-TB3) in the
first display, and terminate on the
“RS422 IN” 6-position controller board
terminal block (A31-TB2) on the second
display. When not using the provided
quick connects cable, the cable should be in conduit.

Figure 34: RS422 Interconnection


Face A RS422 Out

(A31-TB3)

Field Cabling

Face B RS422 IN

(A31-TB2)

Pin 1 (GND)

Shield

Pin 6 (GND)

Pin 2 (D2OUT-N)

Red

Pin 5 (D1IN-N)

Pin 3 (D2OUT-P)

Black

Pin 4 (D1IN-P)

Pin 4 (D2IN-N)

Green

Pin 3 (D1OUT-N)

Pin 5 (D2IN-P)

White

Pin 2 (D1OUT-P)

Pin 6 (Shield)

Pin 1 (Shield)

Electrical Installation