Service and diagnostics, Service and diagnostics -3, 4 service and diagnostics – Daktronics AF-3150-20-R,A User Manual
Page 41

Maintenance and Troubleshooting
4-3
3. The power supplies are set to 3.6 VDC. Power supplies are preset. Contact
Daktronics Customer Service for the proper settings.
4.4 Service
and
Diagnostics
Reference Drawings:
Power Termination Box................................................ Drawing A-129227
Controller, Galaxy, 8-conn J-1087 ............................... Drawing B-177838
Schematics............................................................... Refer to Appendix A
Comp.
Layout Diagram; ........................................... Refer to Appendix A
The following sub-sections address servicing of the following display components:
•
transformer, RFI filter
•
controller
•
modules, drivers and power supplies
The sub-sections also address any diagnostic LEDs, fuses and signal/power
connectors found on the unit. On the Schematics and Component Layout
Diagrams, the components are denoted as follows.
Component… Denoted As…
Location…
Filter and
Transformer
0A-1289-4005
Inside the power termination box
Controller
0A-1229-0005
Depends on the size of the display. (usually
behind the bottom left module, or module
one row above)
Modules
Squares A101 through A309
0A-1266-2004-Red
0A-1266-2005-Amber
Over entire face of the display (includes
driver)
Power Supplies
0A-1289-4011
or
0A-1289-4012
Behind modules (refer to your display’s
Schematic and Component Layout
Diagram)
Light Detector
0A-1247-0003
Behind\below the bottom left module
Modem
0P-1279-0003
Close to the controller, usually in the left end
of the display. Refer to the display’s
Schematic
Fiber Board
0P-1127-0024
Close to the controller, usually in the left end
of the display. Refer to the display’s
Schematic
RS422 Surge
Card
0P-1146-0031
Close to the controller, usually in the left end
of the display. Refer to the display’s
Schematic