beautypg.com

Rs422, Rs422 -11, Figure 25: rs422 display layout – Daktronics AF-3150-20-R,A User Manual

Page 31

background image

RS422

Reference Drawings:

System Riser Diagram, RS422 .................................... Drawing A-174135
Schematic, Internal, W/Quick Connect ........................ Drawing B-177662


An RS422 controlled display requires the use of signal converter near the computer.
From the signal converter, cable is run to the surge board assembly in the display or
to a junction box. The junction box has a quick connect plug, which will be
connected to the display. In either case, the cable from the signal converter to the
surge board must be routed though conduit. Do not run signal and display power
through the same conduit. Refer to

Figure 25

and Drawing A-174135 for system

layout.

1. If using a quick connect cable, terminate the 4-conductor shielded cable at

the signal converter, and to the surge board in the junction box. A quick
connect cable will then go to the RS422 middle jack (J32) on the back of
the primary display.

2. When connecting directly to the display, terminate one end at the signal

converter and the other end of the 4-conductor shielded cable to the 6-
position terminal block on the surge board labeled “RS422 IN” (TB1).
Drawing B-177662 and

Figure 26

below show the terminal block wiring.

3. The computer connects to the signal converter using a DB9 to DB25 serial

cable.

Figure 25: RS422 Display Layout

Electrical Installation

3-11

This manual is related to the following products: