Daktronics Data Time Series 50 Time & Temperature Displays User Manual
Page 27
Electrical
Installation
3-5
The interconnect harness consists of eight (8) digit cables, four(4) power wires, and a
ground wire. Each digit cable has a nine (9) position plug on it. The plugs are labeled
2, 4, 6 … 16.
1. Connect these cables to the jacks along the bottom of the driver inside the master
display, starting with plug 2 on the left end proceeding to plug 16 on the right.
2. Connect the four (4) black power wires to fuses F46-F49 on the power
termination panel. Make sure incoming power is connected to position 3 on TB41,
“02 (120 VAC).”
3. Connect the green ground wire into the earth ground lug, E41, on the power
termination panel. The installer is responsible for protecting the interconnect
harness between the two displays.
3.6.2 48” and 60” Displays
48” and 60” displays do not have the master/slave interconnect harness. The slave
display connects to the master display by a two (2) conductor control cable (Belden
8451, Daktronics part number W-1077). This cable is provided in the slave face.
Route the cable through the conduit to the master display. Connect the cable as
shown:
Cable
TB1
RED
Pin 3
BLK
Pin 4
The installer is responsible for providing conduit to protect the control cable between
the two displays.